Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Dan Med J ; 71(3)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38445315

RESUMO

INTRODUCTION: Continuous peripheral nerve blocks (cPNBs) have shown favourable post-operative pain control results but may be associated with a risk for long-term neurological complications. This study sought to examine factors associated with persistent post-operative pain and potential neuropathy after orthopaedic lower-limb surgery with the use of post-operative cPNB. METHODS: Patients who underwent lower limb orthopaedic procedures with cPNBs between November 2021 to May 2022 were included. Patient demographics and perioperative data were noted. At discharge, patients completed the PainDetect (PD) questionnaire and were followed up six months after discharge. RESULTS: Seventy-seven patients with a total of 171 catheters completed the follow up. The median time to follow-up was 214 days after catheter removal, and 18 patients (23%) had a PD score ≥ 13. Univariate analysis showed that multiple variables were associated with a PD score ≥ 13 at the six-month follow-up. Multiple logistic regression showed that a high PD score at discharge, high BMI and longer duration of cPNBs were associated with higher risk of having a PD score ≥ 13 at the six-month follow-up. CONCLUSION: Several factors were associated with a higher risk of having possible neuropathy after six months. BMI, duration of catheter and PD score at discharge were correlated with risk of possible neuropathic pain. FUNDING: None. TRIAL REGISTRATION: The study was a quality control project and therefore did not require registration under Danish law.


Assuntos
Neuralgia , Procedimentos Ortopédicos , Ortopedia , Humanos , Procedimentos Ortopédicos/efeitos adversos , Neuralgia/etiologia , Dor Pós-Operatória/etiologia , Nervos Periféricos
2.
J Orthop Res ; 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38053300

RESUMO

This study aimed to develop a method using computer vision techniques to accurately detect and delineate the proximal femur in radiographs of Legg-Calvé-Perthes disease (LCPD) patients. Currently, evaluating femoral head deformity, a crucial predictor of LCPD outcomes, relies on unreliable categorical and qualitative classifications. To address this limitation, we employed the pretrained object detection model YOLOv5 to detect the proximal femur on over 2000 radiographs, including images of shoulders and chests, to enhance robustness and generalizability. Subsequently, we utilized the U-Net convolutional neural network architecture for image segmentation of the proximal femur in more than 800 manually annotated images of stage IV LCPD. The results demonstrate outstanding performance, with the object detection model achieving high accuracy (mean average precision of 0.99) and the segmentation model attaining an accuracy score of 91%, dice coefficient of 0.75, and binary IoU score of 0.85 on the held-out test set. The proposed fully automatic proximal femur detection and segmentation system offers a promising approach to accurately detect and delineate the proximal femoral bone contour in radiographic images, which is essential for further image analysis in LCPD patients. Clinical significance: This study highlights the potential of computer vision techniques for enhancing the reliability of Legg-Calvé-Perthes disease staging and outcome prediction.

3.
JMIR Mhealth Uhealth ; 11: e44442, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37283228

RESUMO

BACKGROUND: Smartphones are often equipped with inertial sensors that measure individuals' physical activity (PA). However, their role in remote monitoring of the patients' PAs in telemedicine needs to be adequately explored. OBJECTIVE: This study aimed to explore the correlation between a participant's actual daily step counts and the daily step counts reported by their smartphone. In addition, we inquired about the usability of smartphones for collecting PA data. METHODS: This prospective observational study was conducted among patients undergoing lower limb orthopedic surgery and a group of nonpatients as control. The data from the patients were collected from 2 weeks before surgery until 4 weeks after the surgery, whereas the data collection period for the nonpatients was 2 weeks. The participant's daily step count was recorded by PA trackers worn 24/7. In addition, a smartphone app collected the number of daily steps registered by the participants' smartphones. We compared the cross-correlation between the daily steps time series obtained from the smartphones and PA trackers in different groups of participants. We also used mixed modeling to estimate the total number of steps, using smartphone step counts and the characteristics of the patients as independent variables. The System Usability Scale was used to evaluate the participants' experience with the smartphone app and the PA tracker. RESULTS: Overall, 1067 days of data were collected from 21 patients (n=11, 52% female patients) and 10 nonpatients (n=6, 60% female patients). The median cross-correlation coefficient on the same day was 0.70 (IQR 0.53-0.83). The correlation in the nonpatient group was slightly higher than that in the patient group (median 0.74, IQR 0.60-0.90 and median 0.69, IQR 0.52-0.81, respectively). The likelihood ratio tests on the models fitted by mixed effects methods demonstrated that the smartphone step count was positively correlated with the PA tracker's total number of steps (χ21=34.7, P<.001). In addition, the median usability score for the smartphone app was 78 (IQR 73-88) compared with median 73 (IQR 68-80) for the PA tracker. CONCLUSIONS: Considering the ubiquity, convenience, and practicality of smartphones, the high correlation between the smartphones and the total daily step count time series highlights the potential usefulness of smartphones in detecting changes in the number of steps in remote monitoring of a patient's PA.


Assuntos
Aplicativos Móveis , Smartphone , Humanos , Feminino , Masculino , Estudos de Viabilidade , Exercício Físico , Coleta de Dados
4.
Sensors (Basel) ; 23(5)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36904954

RESUMO

Determining the presence and severity of knee osteoarthritis (OA) is a valuable application of inertial measurement units (IMUs) in the remote monitoring of patients. This study aimed to employ the Fourier representation of IMU signals to differentiate between individuals with and without knee OA. We included 27 patients with unilateral knee osteoarthritis (15 females) and 18 healthy controls (11 females). Gait acceleration signals were recorded during overground walking. We obtained the frequency features of the signals using the Fourier transform. The logistic LASSO regression was employed on the frequency domain features as well as the participant's age, sex, and BMI to distinguish between the acceleration data from individuals with and without knee OA. The model's accuracy was estimated by 10-fold cross-validation. The frequency contents of the signals were different between the two groups. The average accuracy of the classification model using the frequency features was 0.91 ± 0.01. The distribution of the selected features in the final model differed between patients with different severity of knee OA. In this study, we demonstrated that using logistic LASSO regression on the Fourier representation of acceleration signals can accurately determine the presence of knee OA.


Assuntos
Osteoartrite do Joelho , Feminino , Humanos , Articulação do Joelho , Marcha , Caminhada , Aceleração , Fenômenos Biomecânicos
5.
BMJ Open ; 12(9): e062087, 2022 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-36137634

RESUMO

INTRODUCTION: After discharge, patients face multiple risks where timely communication with healthcare professionals is required. eHealth has proposed new possibilities for asynchronous text-based two-way communication between patients and healthcare professionals during this time, and studies show positive effects on clinical outcomes, care coordination and patient satisfaction. However, there are challenges to the adoption of text-based two-way communication, potentially undermining the positive effects in clinical practice. Knowledge of these factors may inform future research and implementations. No reviews have provided an overview of the use of text-based two-way communication after discharge and the identified facilitators and barriers. Therefore, the objective of this scoping review is to systematically identify and map available research that assess the use of text-based two-way communication between patients and healthcare professionals after hospital discharge, including facilitators and barriers to implementation. METHODS AND ANALYSIS: We will include all studies describing the use of text-based two-way communication between patients and healthcare professionals after discharge from hospital. A preliminary search of PubMed (PubMed.gov), EMBASE (Elsevier), CINAHL (EBSCO), PsycINFO (Ovid), Cochrane Library (Wiley), Web of Science (Clarivate) and Scopus (Elsevier) was undertaken on 9 November 2021. The search will be updated for the full scoping review, and reference lists of relevant papers reviewed. Two reviewers will independently screen the literature for inclusion. Data will be extracted and charted in accordance with a data extraction form developed from the research questions and inspired by Consolidated Framework Implementation Research. Findings will be presented in tabular format and a descriptive summary, and reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews checklist. ETHICS AND DISSEMINATION: This scoping review will not require ethics approval. The dissemination strategy involves peer review publication and presentation at conferences.


Assuntos
Pessoal de Saúde , Alta do Paciente , Comunicação , Atenção à Saúde , Hospitais , Humanos , Projetos de Pesquisa , Literatura de Revisão como Assunto , Revisões Sistemáticas como Assunto
6.
Sensors (Basel) ; 22(14)2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35890969

RESUMO

Sensors with a higher sampling rate produce higher-quality data. However, for more extended periods of data acquisition, as in the continuous monitoring of patients, the handling of the generated big data becomes increasingly complicated. This study aimed to determine the validity and reliability of low-sampling-frequency accelerometer (SENS) measurements in patients with knee osteoarthritis. Data were collected simultaneously using SENS and a previously validated sensor (Xsens) during two repetitions of overground walking. The processed acceleration signals were compared with respect to different coordinate axes to determine the test-retest reliability and the agreement between the two systems in the time and frequency domains. In total, 44 participants were included. With respect to different axes, the interclass correlation coefficient for the repeatability of SENS measurements was [0.93-0.96]. The concordance correlation coefficients for the two systems' agreement were [0.81-0.91] in the time domain and [0.43-0.99] in the frequency domain. The absolute biases estimated by the Bland-Altman method were [0.0005-0.008] in the time domain and [0-0.008] in the frequency domain. Low-sampling-frequency accelerometers can provide relatively valid data for measuring the gait accelerations in patients with knee osteoarthritis and can be used in the future for remote patient monitoring.


Assuntos
Osteoartrite do Joelho , Aceleração , Acelerometria , Idoso , Fenômenos Biomecânicos , Marcha , Humanos , Reprodutibilidade dos Testes , Caminhada
7.
Artigo em Inglês | MEDLINE | ID: mdl-34326895

RESUMO

AIM AND OBJECTIVE: The purpose of this study was to explore the capability and Intrarater reliability of thermography in detecting pin site infection. MATERIALS AND METHODS: This is an explorative proof of concept study. Clinical assessment of pin sites was performed by one examiner with the Modified Gordon Pin Infection Classification from grade 0 to 6. Thermography of the pin sites was performed with a FLIR C3 camera. The analysis of the thermographic images was done in the software FLIR Tools. The maximum skin temperature around the pin site and the maximum temperature for the whole thermographic picture were measured. An Intrarater agreement was established and test-retests were performed with different camera angles. RESULTS: Thirteen (four females, nine males) patients (age 9-72 years) were included. Indications for frames: Fracture (n=4), two deformity correction, one lengthening and six bone transport. Days from surgery to thermography ranged from 27 to 385 days. Overall, 231 pin sites were included. Eleven pin sites were diagnosed with early signs of infection: five grade 1, five grade 2 and one grade 3. Mean pin site temperature for each patient was calculated, varied between patients from 29.0°C to 35.4°C (mean 33.9°C). With 34°C as cut-off value for infection, sensitivity was 73%; specificity, 67%; positive predictive value, 10%; and negative predictive value, 98%. Intrarater agreement for thermography was ICC 0.85 (0.77-0.92). The temperature measured was influenced by the camera positioning in relation to the pin site with a variance of 0.2. CONCLUSIONS: Measurements of pin site temperature using the hand-held FLIR C3 infrared camera was a reliable method and the temperature was related to infection grading. CLINICAL SIGNIFICANCE: This study demonstrated that digital thermography with a hand-held camera might be used for monitoring the pin sites after operations to detect early infection. HOW TO CITE THIS ARTICLE: Rahbek O, Husum HC, Fridberg M, et al. Intrarater Reliability of Digital Thermography in Detecting Pin Site Infection: A Proof of Concept Study. Strategies Trauma Limb Reconstr 2021;16(1):1-7.

8.
Scand J Pain ; 21(4): 794-803, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34062627

RESUMO

OBJECTIVES: Continuous peripheral nerve blocks (cPNBs) have shown promising results in pain management after orthopaedic surgeries. However, they can be associated with some risks and limitations. The purpose of this study is to describe our experience with the cPNBs regarding efficacy and adverse events in patients undergoing orthopedic surgeries on the lower extremity in different subspecialties. METHODS: This is a prospective cohort study on collected data from perineural catheters for pain management after orthopedic surgeries in lower limbs. Catheters were placed by experienced anesthesiologists using sterile technique. After an initial bolus dose of 10-20 mL ropivacaine 0.5% (weight adjusted), the catheters were secured and connected to disposable mechanical infusion pumps with ropivacaine 0.2% (basal infusion rate = 6 mL/h; weight adjusted (0.2 mL/kg/h)). After catheterization, the patients were examined daily, by specially educated acute pain service nurses. Pro re nata (PRN) or fixed boluses (10 mL bupivacaine 0.25%; weight adjusted) with an upper limit of 4 times/day, were administered if indicated. Patients' demographic data, physiological status, and pre-op intake of opioids and other analgesics were registered. The severity of post-operative pain was assessed with 'Numeric Rating Scale' (NRS) and 'Face, legs, Activity, Cry, Consolability' (FLACC) scale for adults and children, respectively. The need for additional opioids and possible complications were registered. RESULTS: We included 547 catheters of 246 patients (Range 1-10 catheters per patient). Overall, 115 (21%) femoral, 162 (30%) saphenous, 66 (12%) sciatic, and 204 (37%) popliteal sciatic nerve catheter were used. 452 (83%) catheters were inserted by a primary procedure, 61(11%) catheters employed as a replacement, and 34 catheters (6.2%) used as a supplement. For guiding the catheterization, ultrasound was applied in 451 catheters (82%), nerve stimulator in 90 catheters (16%), and both methods in 6 catheters (1.1%). The median duration a catheter remained in place was 3 days (IQR = 2-5). The proportion of catheters with a duration of two days was 81, 79, 73, and 71% for femoral, sciatic, saphenous, and popliteal nerve, respectively. In different subspecialties, 91% of catheters in wound and amputations, 89% in pediatric surgery, 76% in trauma, 64% in foot and ankle surgery, and 59% in limb reconstructive surgery remained more than two days. During first 10 days after catheterization, the proportion of pain-free patients were 77-95% at rest and 63-88% during mobilization, 79-92% of the patients did not require increased opioid doses, and 50-67% did not require opioid PRN doses. In addition to 416 catheters (76%), which were removed as planned, the reason for catheter removal was leaving the hospital in 27 (4.9%), loss of efficacy in 69 (13%), dislodgement in 23 (4.2%), leakage in 8 (1.5%), and erythema in 4 catheters (0.73%). No major complication occurred. CONCLUSIONS: After orthopaedic procedures, cPNBs can be considered as an efficient method for improving pain control and minimizing the use of additional opioids. However, the catheters sometimes might need to be replaced to achieve the desired efficacy.


Assuntos
Bloqueio Nervoso , Adulto , Anestésicos Locais , Criança , Humanos , Extremidade Inferior/cirurgia , Medição da Dor , Estudos Prospectivos , Nervo Isquiático
9.
Acta Paediatr ; 110(8): 2430-2434, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33914971

RESUMO

AIM: To establish the positive predictive value (PPV) of clinical hip examinations performed by referrers in the Danish screening programme for Developmental Dysplasia of the Hip (DDH) utilising three definitions of true positive DDH diagnosis. METHODS: We retrospectively identified 290 children (169 female) referred during a 4-year period to the orthopaedic outpatient clinic at our institution with a positive clinical hip examination. Positive predictive value was calculated for clinical hip examinations across three definitions of a true positive clinical hip examination for all referrers and subgroups consisting of general practitioners, midwives and paediatricians. The PPV for clinical hip examinations was calculated for paediatric orthopaedic surgeons using one of the three definitions. RESULTS: Positive predictive value of clinical hip examinations for all referrers were 5.4%, 3.6% and 1.8% with the definition of a true positive DDH diagnosis defined as clinical instability found by orthopaedic surgeon, ultrasound classification ≥Graf IIc or both definitions combined, respectively. Positive predictive value of clinical hip examinations performed by orthopaedic surgeons was 33.3% with a true positive clinical examination defined as an ultrasound classification ≥Graf IIc. CONCLUSION: We conclude that the positive predictive value of clinical hip examinations made by referrers in the Danish screening programme for DDH is low.


Assuntos
Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Criança , Feminino , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/epidemiologia , Humanos , Lactente , Recém-Nascido , Triagem Neonatal , Valor Preditivo dos Testes , Estudos Retrospectivos , Ultrassonografia
10.
J Child Orthop ; 14(5): 379-386, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33204345

RESUMO

PURPOSE: Double and triple femoral neck lengthening osteotomies have been described to correct coxa brevis deformity. Only small studies reported the results. Our aim was to provide an overview of the outcomes of double and triple femoral neck lengthening. METHODS: After an extensive search of different online databases, we included studies reporting the results of double and triple femoral neck osteotomies. Clinical and radiological outcomes, and reported complications were extracted. The review process was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. RESULTS: After evaluating 456 articles, we included 11 articles reporting 149 osteotomies in 143 patients (31% male, 64% female, 5% unspecified). Mean age of the patients was 20 years (range 7 years to 52 years). Indications were developmental hip dysplasia (51%), Perthes disease (27%), infection (6%), post-trauma (4%), congenital disorders (2%), slipped capital femoral epiphysis (1%), idiopathic (3%) and unknown (6%). The mean limb length discrepancy reduced by 12 mm (0 mm to 40 mm). In total, 65% of 101 positive Trendelenburg sign hips experienced improvement of abductor muscle strength. An 18% (9% to 36%) increase could be found in functional hip scores. Mean increase in articulo-trochanteric distance was 24 mm (10 mm to 34 mm). Five patients older than 30 years at the time of osteotomy and two younger patients with prior hip incongruency had disappointing results and required arthroplasty. In all, 12 complications occurred in 128 osteotomies, in which complications were reported. CONCLUSIONS: Double and triple femoral neck lengthening osteotomies in coxa brevis show good results with few complications in the literature, especially in young patients with non-arthritic hips. LEVEL OF EVIDENCE: III.

11.
Arch Trauma Res ; 2(1): 36-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24396788

RESUMO

BACKGROUND: Appropriate treatment of acromioclavicular joint dislocation is controversial. Acroplate fixation is one of the most common treatment methods of acromioclavicular joint (ACJ) dislocation. Based on the risk of re-dislocation after Acroplate fixation, we assumed that combined fixation with an Acroplate and a coracoclavicular screw helps improve the outcome. OBJECTIVES: The main purpose of the current study was to compare the outcome of ACJ dislocation treated with an Acroplate alone and in combination with coracoclavicular screw. PATIENTS AND METHODS: This study was carried out on 40 patients with ACJ dislocation types III to VI who were divided randomly into two equal groups: Acroplate group (P) and Acroplate in combination with coracoclavicular screw group (P + S). The screws were extracted 3-6 months postoperatively. The patients were followed for 1 year and Imatani's score was calculated. Finally, the data were compared between the groups. RESULTS: The mean Imatani's score was significantly higher in P + S group (83.4 ± 14.1) than P group (81.2 ± 10.3) (P < 0.001). The mean duration of surgery was the same in the two groups (59.8 ± 9.4 minutes in group P V.s 64.3 ± 10.9 minutes in group P + S; P = 0.169). There were no cases of re-dislocation, degenerative changes and ossification and all patients returned to their previous jobs or sporting activities. CONCLUSIONS: Using a coracoclavicular screw combined with an Acroplate can improve the patients' function after ACJ disruption without any significant increase in surgical duration. Authors recommend this technique in the fixation of ACJ dislocation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...